Ubiquiti Access G3 Gate Starter Kit
Ubiquiti · UA-G3-SK-Gate · EAN 0810177162001
sofort lieferbar
862,50 €inkl. MwSt., zzgl. Versand
Gut geeignet für
- Außenbereich
- Werkstatt & Industrie
- Rechenzentrum
- Büro & Unternehmen
Größere Stückzahl oder Projekt? Projektanfrage stellen — Antwort kommt vom Fachbetrieb, nicht vom Bot.
Beschreibung
Starter kit with a Gate Hub, G3 Intercom, PoE++ adapter, and PoE++ over twisted pair extender for access control at a single gate with Touch Pass support.
Ähnliche Artikel
Technische Daten
- Höhe
- 9,0 cm
- Tiefe
- 40,5 cm
- Breite
- 31,5 cm
- Gewicht
- 3,785 kg
- In the Box
- (1) Gate Hub (1) G3 Intercom (1) PoE++ adapter (2) 2-wire Retrofit Extenders
- Touch Pass
- 10 free 1-year Touch Passes included <a href="https://help.ui.com/hc/en-us/articles/27130425853079-UniFi-Access-Touch-Pass-Configuration" target="_blank" rel="noopener noreferrer">Learn More</a>
- Gate Hub: LEDs
- W/B <a href="https://help.ui.com/hc/en-us/articles/25738084762775-UniFi-Access-Understand-Access-Device-LED-Status-Indicators" target="_blank" rel="noopener noreferrer">Learn More</a>
- Gate Hub: Button
- (1) Factory reset
- Gate Hub: Weight
- 460 g (1 lb)
- G3 Intercom: LEDs
- Amber <a href="https://help.ui.com/hc/en-us/articles/25738084762775-UniFi-Access-Understand-Access-Device-LED-Status-Indicators" target="_blank" rel="noopener noreferrer">Learn More</a>
- G3 Intercom: Size
- 177 mm (7") diagonal
- Gate Hub: Mounting
- DIN-rail (Included)
- G3 Intercom: Weight
- Device: 965 g (2.1 lb) Bracket: 445 g (1 lb)
- G3 Intercom: Buttons
- (1) Factory reset
- G3 Intercom: Sensors
- Proximity sensor ALS sensor
- G3 Intercom: Speaker
- (1) Yes, 2W
- Gate Hub: Dimensions
- 175 x 126 x 26 mm (6.9 x 5 x 1")
- PoE++ Adapter: Model
- U-PoE++
- G3 Intercom: Mounting
- Wall mount, adapter to the gooseneck pedestal (Included) Surface angle, flush mount, sunshield kit (Optional)
- PoE++ Adapter: Weight
- 210 g (7.4 oz)
- G3 Intercom: Luminance
- Max. 1000 nits (Typical)
- Gate Hub: Power Method
- PoE++ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
- Gate Hub: UL 294 Level
- Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
- G3 Intercom: Dimensions
- 324.8 x 113.7 x 28.3 mm (12.8 x 4.5 x 1.1")
- G3 Intercom: Resolution
- 2MP 1200 x 1600 (3:4)
- Gate Hub: Digital Input
- Gate exit request, gate position, side door exit request, side door position, emergency
- Gate Hub: PoE Interface
- (1) PoE++ input, 50V DC, 1A (4) PoE outputs, 50V DC, 30W per port (Max 55W aggregated)
- Retrofit Extender: LEDs
- White
- Gate Hub: Certifications
- CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
- G3 Intercom: Connectivity
- BLE 4.2 NFC
- G3 Intercom: Power Method
- PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
- G3 Intercom: UL 294 Level
- Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
- Gate Hub: Input Terminals
- (1) Gate exit request (1) Gate position (1) Side door exit (1) Side door position (1) Emergency
- Gate Hub: Supported Doors
- 1 gate, 1 side door
- PoE++ Adapter: Dimensions
- 106 x 63 x 34 mm (4.2 x 2.5 x 1.3")
- PoE++ Adapter: Efficiency
- 85+%
- Retrofit Extender: Weight
- PoE in: 77 g (2.7 oz) PoE out: 79 g (2.8 oz) Adapter: 140 g (4.9 oz)
- G3 Intercom: Field of View
- H: 79.4°, V: 97.5°, D: 118.2°
- G3 Intercom: NFC Frequency
- 13.56 MHz
- Gate Hub: Dry Output Relay
- (2) Operator: rated 30V DC, up to 1A (1) Aux: rated 30V DC, up to 1A
- Gate Hub: Other locks (1A)
- 24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
- Gate Hub: UL 294 Statement
- Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power
- G3 Intercom: Certifications
- CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
- G3 Intercom: Mount Material
- Powder-coated stainless steel
- G3 Intercom: NFC Read Range
- < 30 mm (1.18'')
- G3 Intercom: NFC Technology
- ISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340) MIFARE Classic / MIFARE DESFIRE Sony FeliCa™ (ID only) NFC Forum tags T1T, T2T, T3T, T4T and T5T ECP 2.0
- PoE++ Adapter: AC Connector
- IEC-320 C6
- PoE++ Adapter: Power Method
- Universal AC input, 100–240V AC, 50/60 Hz
- PoE++ Adapter: Power Supply
- AC/DC
- G3 Intercom: Max. Frame Rate
- 30 FPS
- G3 Intercom: Weatherproofing
- IP65
- Gate Hub: Enclosure Material
- Polycarbonate
- Gate Hub: Maximum User Count
- 6,000
- PoE++ Adapter: Data In / PoE
- RJ45 shielded socket
- PoE++ Adapter: Input Current
- 1.3A @ 120V AC 0.75A @ 230V AC
- PoE++ Adapter: Output Ripple
- 1% max.
- PoE++ Adapter: Rated Voltage
- 100–240V AC at 50/60Hz
- PoE++ Adapter: Response Time
- <1 ns
- G3 Intercom: UL 294 Statement
- Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power
- PoE++ Adapter: Certifications
- CE, FCC, IC, UL, UKCA, KC, CCC, RoHS
- PoE++ Adapter: Inrush Current
- <100A peak @ 120V AC <200A peak @ 230V AC
- PoE++ Adapter: Output Voltage
- 48V DC @ 1.25A
- Retrofit Extender: Dimensions
- PoE in/out: 40 x 105 x 25 mm (1.6 x 4.1 x 1") Adapter: 43.5 x 138 x 30 mm (1.7 x 5.4 x 1.2")
- G3 Intercom: Screen Technology
- Capacitive multi-touch
- Gate Hub: Networking Interface
- (5) 10/100/1000 Base-T
- Gate Hub: Powered Output Relay
- Side door lock: 12V DC, up to 1A
- Gate Hub: Software Information
- The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
- PoE++ Adapter: 4-pair Powering
- Pins 1, 2, 4, 5 (+) and 3, 6, 7, 8 (-)
- PoE++ Adapter: Line Regulation
- ≤ 1%
- PoE++ Adapter: Load Regulation
- ≤ 3%
- G3 Intercom: Enclosure Material
- Aluminum alloy, UV-stabilized polycarbonate, glass
- PoE++ Adapter: Surge Protection
- Difference and common mode
- Retrofit Extender: Power Method
- PoE++
- Gate Hub: Indoor and Outdoor Use
- Indoor only: device itself Outdoor: with waterproof junction box
- Gate Hub: Management Application
- UniFi Access
- Gate Hub: Max. Power Consumption
- 22W (Without PoE output) 60W (With PoE output)
- PoE++ Adapter: Shunt Capacitance
- <5 pF data
- Retrofit Extender: PoE Interface
- PoE in: (1) PoE++, 50V DC, 1.2A PoE out: (1) PoE+, 48V DC, 0.6A
- G3 Intercom: Networking Interface
- (1) GbE RJ45 port
- G3 Intercom: Software Information
- The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>
- PoE++ Adapter: Peak Pulse Current
- 36A (10/1000 μs) data
- Retrofit Extender: Certifications
- CE, FCC, IC
- Retrofit Extender: Mount Material
- Polycarbonate
- Gate Hub: CAN/ULC-60839-11-1 Grade
- Grade assignment: I
- Gate Hub: PoE Cabling Requirements
- Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge per
- Gate Hub: UA-Lock-Electric (400mA)
- 24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
- PoE++ Adapter: Clamping Protection
- 11V data, 60V power
- PoE++ Adapter: Switching Frequency
- 65 kHz
- G3 Intercom: Max. Power Consumption
- 13W
- PoE++ Adapter: Max. Surge Discharge
- 1500A (8/20 μs) power
- G3 Intercom: Supported Voltage Range
- 48V DC
- Gate Hub: Ambient Operating Humidity
- 5 to 90% noncondensing
- Retrofit Extender: Coaxial Connector
- BNC female
- G3 Intercom: CAN/ULC-60839-11-1 Grade
- Grade assignment: I
- G3 Intercom: PoE Cabling Requirements
- Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge per
- Retrofit Extender: ESD/EMP Protection
- Air: ± 8kV, contact: ± 4kV
- Retrofit Extender: Enclosure Material
- Polycarbonate
- PoE++ Adapter: Supported Voltage Range
- 100–240V AC
- G3 Intercom: Ambient Operating Humidity
- 5 to 90% noncondensing
- Gate Hub: Ambient Operating Temperature
- -30 to 60° C (-22 to 140° F)
- Retrofit Extender: Networking Interface
- (1) 10/100 MbE (1) Homeplug AV
- Gate Hub: UA-Lock-Magnetic-270kg (800mA)
- 24 AWG length: 12 m (39 ft) 22 AWG length: 20 m (66 ft) 20 AWG length: 30 m (98 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
- Gate Hub: UA-Lock-Magnetic-540kg (500mA)
- 24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
- PoE++ Adapter: Ambient Operating Humidity
- 10 to 95% noncondensing
- Retrofit Extender: Max. Power Consumption
- 3W (Without PoE output)
- G3 Intercom: Ambient Operating Temperature
- Device: -30 to 60° C (-22 to 140° F) Display: -25 to 60° C (-13 to 140° F)
- PoE++ Adapter: Ambient Storage Temperature
- -30 to 70°C (-22 to 158° F)
- PoE++ Adapter: Ambient Operating Temperature
- 0 to 40° C (32 to 104° F)
- Retrofit Extender: Ambient Operating Humidity
- 5 to 90% noncondensing
- PoE++ Adapter: Max. PoE+ Wattage per Port by PSE
- 60W
- Retrofit Extender: Ambient Operating Temperature
- -10 to 40° C (14 to 104° F)
- G3 Intercom: Document number, and issue date and/or revision
- UA-G3-Intercom, V01
- Gate Hub: Document number, and issue date and/or revision le
- UA-Hub-Gate, V01